摘要: TianQin is a planned Chinese space-based gravitational wave (GW) observatory
with a frequency band of 10-4 to 1Hz. Optical telescopes are essential for the
delivery of the measurement beam to support a precise distance measurement
between pairs of proof masses. As the design is driven by the interferometric
displacement sensitivity requirements, the stability control of optical path
length (OPL) is extremely important beyond the traditional requirement of
diffraction-limited imaging quality. In a telescope system, the recurring
tilt-to-length (TTL) coupling noise arises from the OPL variation due to the
wavefront deformation and angular misalignment. The pupil aberrations are
preferred option to understand the OPL specifications and further suppress TTL
coupling noise. To correct the pupil aberrations, we derive primary pupil
aberrations in a series expansion form, and then refine the formulation of
merit function by combining the pupil aberration theory and traditional image
aberration theory. The automatic correction of pupil aberrations is carried out
by using the macro programming in the commercial optical software Zemax,
leading to a high performance telescope design. The design results show that on
one side the pupil aberrations have been corrected, and on the other side, its
optical performance meets the requirements for TianQin project. The RMS
wavefront error over the science field of view (FOV) is less than {\lambda}/200
and the maximum TTL coupling noise over the entire 300 urad FOV is
0.0034nm/urad. We believe that our design approach can be a good guide for the
space telescope design in any other space-based GW detection project, as well
as other similar optical systems.